← Back
Details
Date
2024-04-19
Aircraft
N226JA
Type
100hr
Time Readings
TACH 1866.3
SMOH 1630.5
Mechanic
Bob McCammond
Cert #
2211795
Source
N226JA/Aircraft Maintenance Records/CCF05062026_0008.pdf, page 1
OCR Conf.
Description
SMOH 1630.5 Lyco-320 E2D S/N L-34839-27A. Performed 100 hour inspection on engine. Compression 1 thru 4 are 70, 76, 74 & 74, 80 base pressure. Changed oil & oil filter. 7 qts Aeroshell 100 plus & AA 48110-2 filter. Replaced all intake pipe flange gaskets P/N 71973. All spark plugs inspected & serviced, reinstall & torq 360 in/lbs. Work performed I.A.W. Cessna 172 100 hour inspection checklist & Lyc direct drive overhaul maint. man/I.P.C. I certify that this engine was inspected in accordance with 100 hour inspection & was determined to be in airworthy condition at this time. Return to service.
AD / SB / FAR References
TypeNumberDescription
OTHER Cessna 172 100 hour inspection checklist Cessna 172 100 hour inspection checklist
OTHER Lyc direct drive overhaul maint. man/I.P.C. Lycoming direct drive overhaul maintenance manual / IPC
Components
ComponentPart #Serial #Qty
Oil filter AA 48110-2 1
Intake pipe flange gaskets 71973 1
Raw OCR Text
(empty)